EC Example: Only output the data if the bar code begins with a number
If you want only data from bar codes that begin with a number, you can use EC to
check for the number.
Command string: ECF10D
EC is the "Check for a number" command
F1 is the "Send all characters" command
0D is the hex value for a CR
If this bar code is read,
be used on the data. If there is no other format, the format fails and the raw data is
output as AB1234.
If this bar code is read:
1234AB
<CR>
Check for non-numeric character
ED Check to make sure there is a non-numeric ASCII character at the current cursor
position. The format is aborted if the character is numeric.
ED Example: Only output the data if the bar code begins with a letter
If you want only data from bar codes that begin with a letter, you can use ED to
check for the letter.
Command string: EDF10D
ED is the "Check for a non-numeric character" command
F1 is the "Send all characters" command
0D is the hex value for a CR
If this bar code is read,
be used on this data. If there is no other format, the format fails and the raw data is
output as 1234AB.
If this bar code is read:
AB1234
<CR>
182
the next data format, if there is one, will
the data is output as:
the next data format, if there is one, will
the data is output as: