Trigger Commands - Honeywell Xenon Series User Manual

Area-imaging scanners
Table of Contents

Advertisement

This response indicates that Codabar Coding Enable (CBRENA) has a range of val-
ues from 0 to 1 (off and on).
Example: What is the default value for Codabar Coding Enable?
Enter:
Response:
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: What is the device's current setting for Codabar Coding Enable?
Enter:
Response:
This response indicates that the device's Codabar Coding Enable (CBRENA) is set
to 1, or on.
Example: What are the device's settings for all Codabar selections?
Enter:
Response:
This response indicates that the device's Codabar Coding Enable (CBRENA) is set
to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don't Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.

Trigger Commands

You can activate and deactivate the scanner with serial trigger commands. First,
the scanner must be put in Manual Trigger Mode by scanning a Manual Trigger
Mode bar code
(page
deactivated by sending the following commands:
Activate:
Deactivate:
270
cbrena^.
CBRENA1[ACK]
cbrena?.
CBRENA1[ACK]
cbr?.
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
(page
119), or by sending a serial menu command for triggering
121). Once the scanner is in serial trigger mode, the trigger is activated and
SYN T CR
SYN U CR
Xenon/Granit User Guide