Appendix B: FE-100TX, FE-100FX, and FE-100F3 Specifications
B.2

FE-100FX

The FE-100FX shown in
supports multimode fiber optic cabling. Specifications for the FE-100FX
are listed in
Table
Cable Type
50/125 µm fiber optic
62.5/125 µm fiber optic
100/140 µm fiber optic
The transmitter power levels and receive sensitivity levels listed
NOTE
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.
B-2
Figure B-2
B-1, below.
Figure B-2 FE-100FX
Table B-1 Transmitter Power
Worst Case Budget
6.0 dB
9.0 dB
15.0 dB
uses an SC style connector that
Typical Budget
2H23-50R/2H33-37R User's Guide
2286-40
9.0 dB
12.0 dB
18.0 dB