Writing A Project; Training Sequence Program - Mitsubishi Electric Fatec GOT2000 Series Basic Training Textbook

Graphic operation terminal
Hide thumbs Also See for Fatec GOT2000 Series:
Table of Contents

Advertisement

6.2.2

Writing a project

Display the screen for writing the project and write all data to the GOT.
Reset the PLC CPU using the RESET key switch, and then switch to RUN.
6.2.3

Training sequence program

P
O
I
N T
P
O
I
N
To identify the device used for the project data being edited, the Device list function of GT Designer3 will be useful.
Refer to section 5.13 of this textbook for details.
M31
21
Run/Stop
M32
34
Dummy for
ladder
monitor
M33
36
Dummy for
ladder
monitor
M34
38
Operating
42
>=
49
>=
56
>=
61
>=
65
6 - 8
6. About debug
6.2 Training screen creation
X2
Malfunction 1
SM412
1-sec clock
D30
K60
1-sec unit
D31
K60
1-min unit
D32
K24
1-hour unit
D32
K8
1-hour unit
M32
Dummy for
ladder
monitor
M33
Dummy for
ladder
monitor
M34
Operating
INCP
D30
1-sec unit
INCP
D31
1-min unit
RST
D30
1-sec unit
INCP
D32
1-hour unit
RST
D31
1-min unit
RST
D32
1-hour unit
M35
8 hour
operation
END