Mitsubishi Electric Fatec GOT2000 Series Basic Training Textbook page 214

Graphic operation terminal
Hide thumbs Also See for Fatec GOT2000 Series:
Table of Contents

Advertisement

Appendix.3.2 Procedures up to accessing
This section describes the system configurations using the following connection examples:
• Connection between the personal computer and GOT: USB connection
• Connection between GOT and PLC: Ethernet connection
The following shows the procedure before accessing.
Connect the GOT to a Mitsubishi PLC.
Set the communication interface (Communication
Connect the cable.
Access the PLC by GX Works2.
(1) Setting communication interface (Communication settings)
Set the communication interface of the GOT at [I/F Communication Setting] in GT Designer3.
(2) Cable connection
(a)
Connection method for USB cable
App - 30
settings)
Refer to (1) of this section
Refer to (2) of this section
Refer to (3) of this section
1.
Set [CH No.] of [Standard I/F-3] to "9".
1.
2.
Set [Driver] of [Standard I/F-3] to "Host (PC)".
2.
Connect the USB cable to the USB interface on the GOT.

Advertisement

Table of Contents
loading