ELECTRICAL

CHARGING PROCEDURE

If battery voltage is 12.6 Vdc or less, the battery may
need recharging. When using an automatic charger, refer
to the charger manufacturer's instructions for recharging.
Do not exceed 6 amps when charging the battery.
NOTICE
Charge the battery using an automatic charger that will
not exceed 14.6 Vdc. An automatic charger will signal
when charging is complete.
Allow the battery to stand disconnected for at least 1-2
hours after being properly charged. If the voltage drops
below 12.6 volts, charging was ineffective or the battery
needs to be replaced.
An overheated battery could explode, causing severe
injury or death. Always watch charging times carefully.
Stop charging if the battery becomes very warm to the
touch. Allow it to cool before resuming charging.
VOLTAGE
STATE OF
(DC)
CHARGE
12.8 or
100%
more
75% -
12.6 - 12.8
100%
50% - 75%
12.3 - 12.6
25% - 50%
12.0 - 12.3
0% - 25%
12.0 or less
NOTICE
Follow the charger instructions supplied by the
manufacture regarding the order or connections, switch
positions and when to connect the charger to an outlet.
12.26
WARNING
CHARG-
ACTION
E TIME
None, check
None
again in 3
Required
months
May need
3 - 6 hrs
slight charge
Needs
5 - 11 hrs
Charge
Needs
At least
Charge
13 hrs
Needs
At least
Charge
20 hrs