Load Test; Charging Procedure; Off Season Storage - Polaris RANGER 500 2017 Service Manual

Hide thumbs Also See for RANGER 500 2017:
Table of Contents

Advertisement

ELECTRICAL
SPECIFIC GRAVITY
0% Charged
* At 80° F. NOTE: Subtract .01 from the specific gravity
reading at 40° F.

LOAD TEST

A battery may indicate a full charge condition in the OCV
test and the specific gravity test, but still may not have
the storage capacity necessary to properly function in the
electrical system. For this reason, a battery capacity or
load test should be conducted whenever poor battery
performance is encountered.
This is the best test of battery condition under starting
load. Use a load testing device that has an adjustable
load. Apply a load of three times the ampere-hour rating.
At 14 seconds into the test, check battery voltage. A
good 12V battery will have at least 10.5 Volts. If the
reading is low, charge the battery and retest.

CHARGING PROCEDURE

1. Remove the battery to prevent damage from leaking
or spilled acid during charging.
2. Charge the battery with a charging output no larger
than 1/10 of the battery's amp/hr rating. Charge at
0.1Ah for max of 15 hours. The battery is faulty if it
does not achieve a specific gravity of 1.270 after 15
hours.
3. Install battery in vehicle. Coat threads of battery bolt
with a corrosion resistant dielectric grease.
Dielectric Grease:
PN 2871329
4. Connect battery cables.
To avoid the possibility of explosion, connect positive
(+) cable first and negative (-) cable last.
5. After connecting the battery cables, install the cover
on the battery and attach the hold down strap.
12.32
1.115 or less
WARNING
6. Install clear battery vent tube from vehicle to battery
vent.
Vent tube must be free from obstructions and kinks and
securely installed. If not, battery gases could
accumulate and cause an explosion. Vent should be
routed away from frame and body to prevent contact
with electrolyte. Avoid skin contact with electrolyte, as
severe burns could result. If electrolyte contacts the
vehicle frame, corrosion will occur.
7. Route cables so they are tucked away in front and
behind battery.

OFF SEASON STORAGE

See Chapter 2 "Maintenance" for battery service
procedures.
9850043 R01 - 2017-2021 RANGER 500 / 570 Service Manual
WARNING
© Copyright Polaris Inc.

Advertisement

Table of Contents
loading

Table of Contents