5.7.6 Write-protected parameters

5.7.7 Online mode

5.7.8 Offline mode

User Manual V1.01
Some parameters cannot be configured by the user. This mostly concerns those
parameters that affect the safety of the electronic unit or of the connected motors. For
example, the monitoring of the supply voltage cannot be disabled. All parameters that
cannot be edited by the user are displayed shaded.
The user normally works in the Online mode. This means that the LinMot
unit is connected directly to the PC via a serial interface. Changes in the parameters are
transmitted to the LinMot
accessed by logging in and activating the Parameter Inspector from the Commander.
The Offline mode allows the editing of a parameter configuration that was saved
beforehand. The electronic unit doesn't need to be connected to the serial interface for
this operation. Changes to the parameters are not transmitted directly to the electronic
unit, but the modified configuration can be saved. The Offline mode can be accessed by
selecting the "Offline Edit..." command under the "File" menu.
Not all parameters are available in the Offline mode. The parameter "Time", for
example, is not available, as it would normally display the time of operation of an
electronic unit and there is no connection to an electronic unit in this mode. All the
parameters that cannot be read in the Offline mode are marked with "n.a." (not
available).
Configuration Software
®
electronic unit over the interface. The Online mode is