Advertisement

PROFIBUS Interface

4 PROFIBUS Parameters

The PROFIBUS drives have an additional parameter tree branch, which can be configured
with the distributed LinMot-Talk software. With these parameters, the PROFIBUS behaviour
can be configured. The software LinMot-Talk can be downloaded from
under the section download, software & manuals.
Dis-/Enable
Node Address
Node Address Selection
Node Address Parameter Value
Byte Order
NTI AG / LinMot
With the Dis-/Enable parameter the LinMot drive can be run without
the PROFIBUS going online. So in first step the system can be
configured and run without any bus connection.
PROFIBUS Interface\ Dis-/Enable
Disable
The drive runs without PROFIBUS.
Enable
The drive runs only with a PROFIBUS connection.
IMPORTANT: To activate the PROFIBUS Interface, the Dip-Switch
S3.4 "Interface" at the bottom of the drive has to be set to "ON"
S3
ON – OFF
Interface
CAN Term
RS485 Term
RS485/232
This directory contains the parameters defining the node address.
The node address selection parameter defines the source of the node
address.
PROFIBUS Interface\ Node Address\ Node Address Selection
By Hex
The node address is determined by the two Hex
Switches
Switches S1 (ID High) and S2 (ID Low)
Attention, the ID defined by S1 and S2 is
hexadecimal coded and not decimal!
By Parameter
The node address is determined by the parameter
"Node Address Parameter Value".
By default, the node address is set by the rotary switches S1 and S2.
IMPORTANT: The rotary switches are hexadecimal.
According to the PROFIBUS standard the maximal
node address is 127 (addresses 126 and 127 are
reserved for special purpose and should normally not
be used).
Defines the node address when "By Parameter" is selected.
Defines the used byte order.
PROFIBUS Interface\ Byte/Word Order\Byte Order
Reversed
Byte order is reversed. For S7 PLCs select
reversed.
Not reversed
Byte order is not reversed.
User Manual PROFIBUS Interface / 15/05/2012