Setting The Recording Variables; Setting The Trigger Mode - LinMot Step User Manual

Table of Contents

Advertisement

   
LinMot

5.9.1 Setting the recording variables

5.9.2 Setting the trigger mode

Trig on Level
Trig on Curve
User Manual V1.01
By setting the recording variables the user specifies which variables are to be sampled
during the recording process. The variables panel must be activated before setting the
variables (see also Figure 5-11). For each of the two channels the user can select the
variable from a list. In case of drive variables the user must also specify the
corresponding drive.
The trigger mode defines when the recording should be started. The following trigger
modes are available:
The recording is started when the selected variable exceeds, res. falls below the
threshold specified. In Figure 5-13 the trigger is set to start the recording when the
actual position of drive A exceeds the given position.
Figure 5-13: Trigger mode 'Trig on level'
The recording is started when the selected curve is started. In Figure 5-14 the trigger is
set to start the recording when curve 2 is started on drive A.
Figure 5-14:Trigger mode 'Trig on curve'
Configuration Software
Figure 5-12: The variables panel
5-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

MagnetPE