LinMot
SYS2 interface
COM interface
User Manual V1.01
The SYS2 interface is configurable for the operation with CAN bus. The CAN bus is not
supported in normal operation and requires the implementation of a customer specific
protocol. For further questions regarding CAN bus coupling please contact Sulzer
Electronics AG.
The jumper positions for SYS2 must not be changed, otherwise the inputs for the set
values will no longer be available.
By default the electronic unit is configured for operation with the analog inputs for the
set values and the trigger signals. The jumper positions for SYS2 must not be changed,
otherwise the inputs for the set values will no longer be available.
The Com interface for configuring the electronic unit via the PC software LinMot
is normally operated in the RS232 mode. Upon request an RS485 interface is available.
For further information regarding the RS485 interface please contact Sulzer Electronics.
By default the unit comes configured for operation with the RS232 interface.
Design and Installation
J101
AN_IN_2/4
AN_IN_2
AN_IN_4
GND
Com
Sys2
Figure 4-19: Configuration SYS2
J101
RS232
RS232_TX
RS232_RX
GND
Com
Sys2
Figure 4-20: Configuration COM
4-24
Sys2
Pin 2
Pin 7
Pin 5
J510
J511
Sys1
Com
Pin 2
Pin 3
Pin 5
J510
J511
Sys1