Hw Configuration Of The Electronic Units; Signal Board Configuration - LinMot Step User Manual

Table of Contents

Advertisement

   
LinMot

4.8 HW configuration of the electronic units

4.8.1 Signal board configuration

SYS1 interface
User Manual V1.01
The electronic units consist of a signal board and a power board that you can configure
to suit your own requirements.
To configure the boards you must remove the heat sink and open the case. This is done
by removing all the screws. The two boards are kept in place by spacers and connected
by means of post connectors. When opening the unit and handling the electronic boards
the usual care should be taken in observing the necessary measures to prevent
electrostatic discharge that would otherwise damage the boards (ESD-mats, ground
connection, ..).
Further care must be taken in order not to damage or stress either mechanical or
electrical components, as this could lead to malfunction or damage.
Caution: The electronic unit must be completely assembled and closed in its case before
it can be put back into operation.
The two electronic unit series E100/E200/E400 and E1000/E2000/E4000 differ only in
the execution of the power board. The signal boards are absolutely identical and for this
reason the explanations in this section are valid for both.
The interfaces to the higher-level control system can be configured on the signal board.
Only the following jumper positions result in usable configurations of the electronic
unit.
Instead of the digital open-collector outputs, relay closers or openers can be configured
to act as outputs.
Hint: If the relay output is needed, it is preferable to use the closer contact, because
when using the opener contact the digital output signal for the position monitoring is no
longer available.
By default the electronic unit is configure for operation with the output signal for the
position monitoring (open collector output) and the relay closer contact.
Design and Installation
J101
DIG_OUT / RELAIS
J510: DIG_OUT_OC_4
J510: RELAIS_CLOSER
J511: DIG_OUT_OC_3
J511: RELAIS_OPENER
Com
Sys2
Figure 4-18: Configuration SYS1
4-23
Sys1
Pin12.
Pin12.
Pin11.
Pin11.
J510
J511
Sys1

Advertisement