Table 4-22 Internal Relay Outputs; Table 4-23 Punch Block Pinouts - Motorola iDEN Site Controller System Manual

Gen 3
Table of Contents

Advertisement

Gen 3 Site Controller System Manual

Table 4-22 Internal Relay Outputs

Alarm Code
238
239
240
NO = Normally Open.
NOTE:
68P80801E30-A 5/1/2002
Contact
NO
COM
NO
COM
NO
COM
EAS/EAS2 Connector Pinouts
EAS/EAS2 connectors and punch block information appear in Table 4-23.
Only the alarm code number is passed to the OMC. The alarm code is the
software message relating the punch block pins with the alarm.

Table 4-23 Punch block pinouts

Alarm
EAS/EAS2
code
connector
201
User Alarm/Control
202
User Alarm/Control
203
User Alarm/Control
204
User Alarm/Control
205
User Alarm/Control
206
User Alarm/Control
207
User Alarm/Control
208
User Alarm/Control
209
User Alarm/Control
P5 (CONTROL) Pin No.
3
4
5
6
7
8
Punch
block
pairs
6, 31
customer defined input
5, 30
customer defined input
14, 39
customer defined input
13, 38
customer defined input
12, 37
customer defined input
11, 36
customer defined input
10, 35
customer defined input
9, 34
customer defined input
8, 33
customer defined input
Chapter 4 Installation
Intercabling Connections
Function
output, RF Relay Cabinet
1
output, RF Relay Cabinet
2
output, RF Relay Cabinet
3
EAS/EAS2 standard
alarm connection
4-47