Chapter 6 System Testing
Base Radio Registration
6-16
Cab/Pos number will not be displayed for Quad BRs with invalid cabinet/
position number and BRs that don't respond successfully.
iSC> ping br
Cab/Pos
Ethernet Address
---------
---------------------
08:00:3e:c0:1c:18
08:00:3e:c0:1c:19
No information will be displayed for BRs that fail to respond at all.
The service computer displays the following messages if the site controller
cannot communicate with any BR.
iSC> ping br
No BR responses received for 'ping br'
Ping br is not successful
Perform the following steps in case of unsuccessful response from one or
more BRs:
Check the ethernet connection.
1.
Check BR cabinet/position number.
2.
Reset the BR.
3.
Gen 3 Site Controller System Manual