Ethernet Intercabling - Motorola iDEN Site Controller System Manual

Gen 3
Table of Contents

Advertisement

Chapter 4 Installation
Intercabling Connections
0112004Z29
0112004Z29
0112004Z29
OUT 3
OUT 2
OUT 1
10B2-3
10B2-2
10B2-1
TX OUT
GPS A
GPS B
RX3
RX2
5MHz/1PPS
ETHERNET
SITE GROUND
SITE GROUND
CABINET w/ iSC
Figure 4-8
5 MHz/1 PPS connections

Ethernet intercabling

4-24
0112004Z29
IN
OUT
IN
OUT
ALARM
RX3
RX2
RX1
IN
OUT
IN
ETHERNET
5 MHz/1PPS
ETHERNET
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
RF CABINET #3
RF CABINET #6
0112004Z29
IN
OUT
IN
OUT
ALARM
RX3
RX2
RX1
IN
OUT
IN
ETHERNET
5 MHz/1PPS
ETHERNET
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
RF CABINET #2
RF CABINET #5
0112004Z29
RX1
IN
OUT
IN
OUT
ALARM
RX3
RX2
RX1
IN
OUT
IN
ETHERNET
5 MHz/1PPS
ETHERNET
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
RF CABINET #1
RF CABINET #5
All Ethernet connections are made on the junction panels of the cabinets.
The connections are labeled ETHERNET IN and ETHERNET OUT.
Figures 4-9 through 4-12 show the required intercabling for various EBTS
site configurations. Table 4-15 correlates the specific types of systems and
sites to Figures 4-9 through 4-12.
Ethernet Cabling Procedure
Perform Ethernet cabling between cabinets as follows:
On the cabinet containing the site controller, locate the free end of
1.
the cable
(PN 0112004Z29) connected to the 10B2-1 connector on the
junction panel.
Connect free end of cable to ETHERNET IN connector on RF
Cabinet(s).
{
0112004Z29
OUT
ALARM
RX3
RX2
RX1
5 MHz/1PPS
0112004Z29
IN
OUT
IN
OUT
ALARM
RX3
RX2
ETHERNET
5 MHz/1PPS
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
RF CABINET ... n
{
0112004Z29
OUT
ALARM
RX3
RX2
RX1
5 MHz/1PPS
0112004Z29
IN
OUT
IN
OUT
ALARM
RX3
RX2
ETHERNET
5 MHz/1PPS
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
RF CABINET ... n
{
0112004Z29
OUT
ALARM
RX3
RX2
RX1
5 MHz/1PPS
0112004Z29
IN
OUT
IN
OUT
ALARM
RX3
RX2
ETHERNET
5 MHz/1PPS
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
RF CABINET ... n
Gen 3 Site Controller System Manual
0909906D01
{
T erminator
IN
OUT
IN
OUT
ALARM
RX3
RX2
RX1
ETHERNET
5 MHz/1PPS
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
LAST RF CABINET
RX1
0909906D01
{
T erminator
IN
OUT
IN
OUT
ALARM
RX3
RX2
RX1
ETHERNET
5 MHz/1PPS
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
LAST RF CABINET
RX1
0909906D01
{
T erminator
IN
OUT
IN
OUT
ALARM
RX3
RX2
RX1
ETHERNET
5 MHz/1PPS
CAUTION: DO NOT CONNECT THE ETHERNET CABLES
TO ANY OTHER PORTS; MAY CAUSE INTERNAL DAMAGE
LAST RF CABINET
RX1
iSC098
042301JNM
68P80801E30-A 5/1/2002