Chapter 6 System Testing
Site Controller Verification
6-6
For ProComm users: The following versions are supported:
Note:
• ProComm Plus version 1.1b
• ProComm (all versions)
• ProComm Plus for Windows™ (all versions)
Start the service computer. For the appropriate startup procedure,
1.
refer to the Service Computer Startup section in this chapter.
Power up Controller A.
2.
After the self-test is complete on Controller A, verify that the
3.
following messages appear on the service computer terminal:
Access Controller Gateway
Firmware Rev RXX.XX.XX (PowerPC)
Copyright (c) 2000
Motorola, Inc.
Unauthorized Access Prohibited
Current status:
Active/Standby Status:
MAC Address:
To enter configuration mode, hit any key within 10 seconds:
Press any key within 10 seconds. When prompted, enter the proper
4.
password and press return.
The display does not reflect the entry of the password.
Note:
The default password is factory.
The ACG# prompt is displayed on the service computer once the
correct password has been entered.