Table 4-18 System Alarm Inputs - Motorola iDEN Site Controller System Manual

Gen 3
Table of Contents

Advertisement

Chapter 4 Installation
Intercabling Connections

Table 4-18 System Alarm Inputs

Alarm Code
EAS (D-SUB 50 CONN.)
RETURN
210
224
241
249
250
251
247
246
245
244
243
242
223
222
221
220
219
4-44
P10 (SYSTEM ALARM / CONTROL) Pin No.
Signal (Live)
Connection
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
22
21
24
23
26
25
28
27
30
29
32
31
34
33
36
35
38
37
EAS2 (CHAMP 50 CONN.)
Signal (Live)
RETURN
Connection
23
48
22
47
21
46
20
45
19
44
18
43
17
42
16
41
15
40
14
39
13
38
12
37
11
36
10
35
9
34
8
33
7
32
Gen 3 Site Controller System Manual
Function
reserved for system use
reserved for system use
reserved for system use
reserved for system use
reserved for system use
reserved for system use
major rectifier failure
minor rectifier module
failure
breaker failure alarm
high DC voltage
low DC voltage
AC Power failure
predefined input, site AC
surge protector
predefined input, site smoke
detector
predefined input, site low
ambient temperature
predefined input, site high
ambient temperature
predefined input, site entry