Motorola iDEN Site Controller System Manual page 182

Gen 3
Table of Contents

Advertisement

Chapter 8 Software Commands
Site Controller Commands
CUSTOMER OUTPUT
MONITOR
SELFTEST
8-12
Quad BR must be switched to the test mode, by pressing the
Note:
diagnostic reset button located on the BR front panel, in order to
communicate with iSC. Refer to System Testing section in Volume 1
(System Installation and Testing) of EBTS manual for more
information.
Syntax:
customer output <activate/deactivate>
The 'customer output' command activates or deactivates the customer output.
Example:
iSC> customer output activate
Syntax:
monitor <off | gps | external | 5mhz>
The 'monitor' command selects the input source of the front panel monitor
port.
The user can monitor the following:
iSC> monitor off -- no signal (default)
iSC> monitor gps --GPS 1pps
iSC> monitor external -- External 1pps
iSC> monitor 5mhz -- 5MHz clock
The 'selftest' command executes a series of hardware tests and reports results
to the user.
Gen 3 Site Controller System Manual