Gen 3 Site Controller System Manual

Base Radio Registration

68P80801E30-A 5/1/2002
Checking Base Radio connectivity
At the iSC> prompt, type: ping br
1.
All Base Radios connected on the ethernet will be pinged.
Quad BR must be switched to test mode, by performing diagnostic
Note:
reset (press reset button located on the BR front panel and follow on
screen instructions), in order to communicate with iSC. Refer to
System Testing section in Volume 1 (System Installation and
Testing) of EBTS manual for more information.
Verify the following messages on the service computer.
2.
Cab/pos number and ethernet address will be displayed for BRs that
respond successfully:
iSC> ping br
Cab/Pos
Ethernet Address
----------
----------------------
11
08:00:3e:c0:1c:10
12
08:00:3e:c0:1c:11
13
08:00:3e:c0:1c:12
14
08:00:3e:c0:1c:13
21
08:00:3e:c0:1c:14
22
08:00:3e:c0:1c:15
31
08:00:3e:c0:1c:16
32
08:00:3e:c0:1c:17
The column Cab/Pos represents cabinet and position of the Base Radio. For
example, 13 is the Base Radio in cabinet 1 position 3.
BR position 1 (BR1) represents the BR mounting position within the
Note:
cabinet which is closest to the floor. Position 5 represents the highest
from the floor.
Chapter 6 System Testing
Base Radio Registration
Platform
-------------
Legacy BR
Legacy BR
Legacy BR
Legacy BR
Quad BR
Quad BR
Quad BR
Quad BR
6-15