Table 4-25 Punch block 2 (user alarm) pinouts — continued
Alarm
code
EAS/EAS2 function
213
RFC #6 combiner/multicoupler
amplifier
214
RFC #6 combiner/multicoupler
power supply
215
RFC #6 tower top amplifier
216
RFC #5 circuit breaker
217
RFC #5 combiner/multicoupler
amplifier
218
RFC #5 combiner/multicoupler
power supply
252
RFC #5 tower top amplifier
255
customer-defined output
256
customer-defined output
Pinout connections in "Punch block 2 (left side)" column indicate pins where jumpering between punch block 2 left and
NOTE:
right sides is required. Install jumper from pin specified in "left side" column to the pin specified immediately to the right in
"right side" column. For example, on alarm code 217, jumper is to be installed from punch block left-side, pin 39 to punch
block right-side, pin 17.
68P80801E30-A 5/1/2002
Punch block 2
signal pairs (left side)
(NOTE)
43
18
42
20
45
17
40
15
39
14
38
16
41
13
Chapter 4 Installation
Intercabling Connections
Punch block 2
signal pairs (right side)
21
46
20
45
19
44
18
43
17
42
16
41
15
40
26
2
1
28
4
3
4-55