Motorola iDEN Site Controller System Manual page 115

Gen 3
Table of Contents

Advertisement

Gen 3 Site Controller System Manual
68P80801E30-A 5/1/2002
Table 4-23 Punch block pinouts — continued
Alarm
EAS/EAS2
code
connector
231
RF #2
232
RF #2
233
RF #1
234
RF #1
235
RF #1
236
RF #1
237
CONTROL
238*
CONTROL
239*
CONTROL
240*
CONTROL
241
System/Alarm Control
242
System/Alarm Control
243
System/Alarm Control
244
System/Alarm Control
245
System/Alarm Control
246
System/Alarm Control
247
System/Alarm Control
248*
System/Alarm Control
249
System/Alarm Control
250
System/Alarm Control
251
System/Alarm Control
252
User/Alarm Control
Chapter 4 Installation
Intercabling Connections
Punch
block
EAS/EAS2 standard
pairs
alarm connection
5, 8
RF Cabinet 2 combination/mc
power supply
7, 4
RF Cabinet 2 Tower Top
Amplifier
1, 2
RF Cabinet 1 circuit breaker
3, 6
RF Cabinet 1 combination/mc
amplifier
5, 8
RF Cabinet 1 combination/mc
power supply
7, 4
RF Cabinet 1 Tower Top
Amplifier
1, 2
Control Cabinet circuit
breaker
3, 4
output, RF Relay Cabinet 1
5, 6
output, RF Relay Cabinet 2
7, 8
output, RF Relay Cabinet 3
21, 46
reserved for system use
12, 37
AC Power failure
13, 38
low DC voltage
14, 39
high DC voltage
15, 40
breaker failure alarm
16, 41
minor rectifier module failure
17, 42
major rectifier failure
30, 6, 5
customer defined output.
generator remote start
20, 45
reserved for system use
19, 44
reserved for system use
18, 43
reserved for system use
15, 40
customer defined input
4-49