Problem
The glow circuit does not operate properly.
Engine cranks (but should not) with the reel
on/off switch in the ON position.
Problem
Engine kills during operation (operator sitting
on seat).
Engine kills when the backlap switch is in the
BACKLAP position and the parking brake is
ON.
Battery does not charge.
Possible Causes
Wiring in the glow circuit (see
Schematic (page
damaged.
The glow relay or glow plug controller is faulty.
Fuse F4 is blown or faulty.
The reel on/off switch is faulty or short circuited.
Short circuit in reel drive neutral switch circuit.
Possible Causes
Operator moved too far forward on seat (seat
switch is not depressed).
The engine overheated.
The parking brake was engaged or the parking
brake switch No. 1 failed.
The seat relay or seat switch failed.
The high temperature shutdown relay failed.
Fuse F1 or F3 failed.
The run solenoid or fuel pump failed.
Wiring in the run circuit (see
Schematic (page
The parking brake was released or the backlap
switch was moved to MOW.
The engine overheated.
The traction pedal was moved from the neutral.
The high temperature shutdown relay failed.
Fuse F1 or F3 failed.
The run solenoid or fuel pump failed.
Wiring in the run circuit (see
Schematic (page
Loose or broken wire(s).
Faulty alternator.
Dead battery.
Alternator warning lamp is faulty or burned out.
Alternator warning lamp wiring loose, corroded
or damaged.
Page 3–7
B Electrical
A–6)) is loose, corroded, or
B Electrical
A–6)) broke or disconnected.
B Electrical
A–6)) broke or disconnected.