Glow Controller - Toro Reelmaster 3100-D Service Manual

Hide thumbs Also See for Reelmaster 3100-D:
Table of Contents

Advertisement

Glow Controller

Controller Operation
Controller Checks
Reelmaster
®
3100-D/3105-D
20252SL Rev A
g346552
1.
Glow controller
The controller is located under the right lower corner of the control panel
141).
Note: Refer to the Electrical Schematics in
troubleshooting the glow controller circuit.
1. When the key switch is turned to the RUN position, the controller energizes
the glow plugs and lights up the glow lamp for approximately 6 seconds.
2. When the key switch is held in the START position, the glow plugs will
energize while the switch is held in START and the glow lamp will not light.
3. When the key switch is released from START to RUN, the glow plugs will
de-energize and the glow lamp will remain off.
1. Ensure that there is power from the battery.
2. Disconnect the electrical connector to the fuel stop solenoid to prevent the
engine from starting.
3. Turn the key switch to the RUN position. Check the following while in the
RUN position:
A. Glow indicator lamp is on.
B. Glow relay is energized.
C. Glow plugs are energized.
D. Glow indicator lamp goes out and glow plugs de-energize after
approximately 6 seconds.
4. Turn the key switch to the START position. Check the following while in
the START position:
A. Glow indicator lamp is out.
B. Glow relay is energized.
C. Glow plugs are energized.
D. Power exists at terminal 1 of the glow controller.
Note: If there is no power to terminal 1 of the glow controller, check the
continuity of the circuitry from the key switch to the glow controller and
perform step 4 again; refer to the Electrical Schematics in
A–1).
Figure 141
2.
SCM
Appendix A (page A–1)
Page 6–41
when
Appendix A (page
Electrical System: Component Testing
(Figure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reelmaster 3105-d031700317103174

Table of Contents