2.6

STARTUP

2.6.1 GENERAL

Upon initial startup, the computer prompts the operator to define and enter the
basic operating parameter information necessary for a specific application. These
parameters include the system configuration; scaling of pressure, temperature and
differential pressure inputs, etc.
The operator entry of the startup data is
accomplished by a "Startup Prompting Sequence" with the computer displaying
each parameter name or mnemonic in succession and the operator entering the
required value.
A Data Entry Example/Guide, Table 2-1a, is provided as a data entry aid.
Complete this form for your usage before beginning the Startup Prompting
Sequence. You will normally need to adjust the configuration placed in the unit
by the factory to your particular usage. Table 2-1b includes the printer output
options and the Frequency Densitometer (if used) Options.
No automatic
prompting occurs for these options.
Note that an internal memory support battery maintains all "startup" parameters in
the computer memory for a minimum of 45 days without power input. This
prevents repeating the Startup Prompting Sequence after a short-term shutdown or
a power failure. Additionally this feature allows the computer to be set up at the
factory or elsewhere and then shipped to the field without loss of these key
parameters.