DANIEL 2234 Manual page 70

Table of Contents

Advertisement

__________________________ MODEL 2234 DIGITAL FLOW COMPUTER
Table 2-5. Error Code Diagnostic Chart
Error Code
Possible Cause
12
1. The full scale mass
Excessive
rate is too high.
mass rate
output
13
1. Setting of full scale
Invalid ratio
value(s) too high for
of line
differential line
differential
pressure; low zero
pressure to
scale for static
static
pressure
pressure
14
1. Setting of full scale
Abnormal
value(s) too low for
value for line
differential line
extension
pressure and/or low
factor
zero scale for static
pressure.
15
1. The computer has
Power failure
experienced a power
or watchdog
failure (and possibly a
timeout
restart) since errors
were last cleared.
58
Check
1. Check full scale
mass rate (read code
11) LBHR.
1. Check full scale
value of differential
pressure for individual
lines (read codes 231,
232, 233, 234 and
235) H2O.
1. Check full scale
value of differential
pressure for individual
lines (read codes 231,
232, 233, 234 and
235) H2O.
2. Check zero scale
value of static pressure
(read code 10) PSIA
(Continued)
Solution
1. Enter correct full
scale value per
paragraph 3.6.4.
1. Enter correct full
scale value per
paragraph 3.6.1.
1. Enter correct full
scale value(s) per
paragraph 3.6.1.
1. Enter correct zero
scale value per
paragraph 3.6.1.
1. Enter command
code 0 and CLR the
error codes.
SECTION 2

Advertisement

Table of Contents
loading

Related Products for DANIEL 2234

Table of Contents