MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
Code No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
19
20
21
SECTION 3
Table 3-3. Error Codes
Description
Analog density transducer out of range
Temperature transducer out of range
Static pressure transducer out of range
Line 1 differential pressure transducer under range
Line 2 differential pressure transducer under range
Line 3 differential pressure transducer under range
Line 4 differential pressure transducer under range
Line 5 differential pressure transducer under range
Indicates product temperature is beyond range of API-2565
(i.e., less than 65
Indicates line pressure is beyond range of API-2565 (i.e., less
than 200 psia or greater than 2099.9 psia)
Total volume incremented faster than 25 HZ
Invalid ratio of pipe I.D. to orifice diameter
Rate output overscale
Ratio of line differential to static pressure greater than 4
Extension less than 5
Power failure of watchdog timeout
Frequency density transducer out of range
Measured or calculated density is greater than the full scale
value entered by the operator
Measured or calculated density is less than the zero value
entered by the operator
Line 1 differential pressure over range
o
F or greater than 166.9
o
F)