MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
Command
Title
Code
0
Display
Errors
1
Display
Always ON
2
Display
Timeout
5
Display
Configuration
06m
Use
Densitometer
Input
7
Use API-2565
8
Display
Calculation time
12
Disable Error
Code 8
13
Enable Error
Code 8
14
Display Error
Code 8
15
Clear Print
Table
80n
Gross
Total Reset
SECTION 3
Table 3-2. Command Code Listing
Action
Causes the consecutive display of errors
by Error Code Number
Causes the display to be ON
continuously
Causes the display to be ON temporarily,
(for one minute) and then be replaced
with a blinking asterisk
Causes the display of the configuration
type entered during startup
Selects type of density input for rate and
totals calculations
Instructs the computer to use API-2562
density calculation as density input
Causes the display in seconds of the
length of calculations being performed
by the computer
Turns OFF low temperature alarm
Turns ON low temperature alarm
Causes the display of alarm status for
low temperature
Clears all 32 data locations of the Print
Table and replaces with NOT USED
Resets the flow totals for the station or
line (n) selected
Reference
Paragraph
3.7.2
3.7.1
3.7.1
3.7.3
3.7.1
3.7.1
3.7.3
3.7.1
3.7.1
3.7.1
3.8
3.7.4