MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
B.
Pipe Diameter
D = ID [1 + LA (TF - LT)]
where,
C.
Beta
B = d/D
where,
SECTION 3
D
=
Corrected pipe diameter, inches at TF
ID
=
Measured pipe diameter, inches at LT
LA
=
Pipe coefficient of thermal expansion
TF
=
Fluid temperature, degrees F
LT
=
Pipe measurement temperature, degrees F
B
=
the computed Beta ratio at TF
d
=
Corrected orifice diameter, inches at TF
D
=
Corrected pipe diameter, inches at TF