__________________________ MODEL 2234 DIGITAL FLOW COMPUTER
Table 2-5. Error Code Diagnostic Chart
Error Code
Possible Cause
21
1. Pressure transducer
Line 1
not used for line 1.
differential
pressure over
range
2. Pressure out of
range, transducer
malfunctioning or mis-
calibrated, wiring
error.
22
1. Pressure transducer
Line 2
not used for line 2.
differential
pressure over
range
2. Pressure out of
range, transducer
malfunctioning or mis-
calibrated, wiring
error.
60
Check
1. Check VAR value
of read code 261
(H2O).
2. Check code number
entered for CONFIG
(system configuration),
command code 5.
1. Check VAR value
of read code 262
(H20).
2. Check code
number entered for
CONFIG (system
configuration),
command code 5.
(Continued)
Solution
1. Enter new
CONFIG code
number.
1. Check wiring.
2. Verify pressure.
3. Check transducer.
1. Enter new
CONFIG code
number.
1. Check wiring.
2. Verify density.
3. Check transducer.