MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
Table 2-5. Error Code Diagnostic Chart
Error Code
Possible Cause
31
1. Possibly 24 volt
five volt
circuit is out of
calibration
tolerance.
error
SECTION 2
Check
1. Check voltage on
PC Board 1 with a
digital voltmeter for
5.000 volt.
Check command code
99 for FIC.
(Continued)
Solution
1. Adjust 24-volt
supply output for
5.000 volts per
paragraph 4.2.4.
2. Perform reference
and rate voltage
calibrations per
paragraphs 4.3.1 and
4.3.2.
63