MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
The following table lists all read codes, the display literal, mode capability
(fixed/variable), units display, a description and fixed entry limits as applicable for
the new version of software.
Code Literal
0
DEN
1
TF
2
PF
3
MU
4
IE
5
TFS
6
TZ
7
DFS
8
DZ
9
PFS
10
PZ
11
MFS
12
DOF
13
DZ
17
TK
18
WHT
29
TC
30
A0
31
A1
32
A2
33
DTC
34
CT
35
P0
36
K
37
DCF
42
A4
43
A5
44
DLY
SECTION 3
Table 3-1. Read Codes
Mode Units
F/V
LBF3
F/V
DEGF
F/V
PSIA
F/V
CP
FXD --
FXD DEGF
FXD DEGF Zero Scale Temperature
FXD LBF3
FXD LBF3
FXD PSIA
FXD PSIA
FXD LBHR
FXD LBF3
FXD LBF3
FXD --
F/V
LBHR
FXD --
FXD --
FXD --
FXD --
FXD --
FXD DEGF Densitometer Cal. Temperature None
FXD --
FXD --
FXD --
FXD --
FXD --
FXD MSEC
Description
Density
Measured Temperature
Measured Pressure
Fluid Viscosity
Isentropic Exponent
Full Scale Temperature
Density Full Scale
Density Zero
Pressure Full Scale
Pressure Zero
Mass Rate Full Scale
Density Output Full Scale
Density Output Zero
Station Totalizing Factor
Station Total Mass Rate
Temperature Coefficient
Densitometer Scaling Constant None
Densitometer Scaling Constant None
Densitometer Scaling Constant None
Densitometer Temp. Correction None
Pressure Coefficient
Pressure Coefficient
Densitometer Corr. Factor
Pressure Coefficient
Pressure Coefficient
Printer Line Delay
Fixed limits
>0.1
-50 to 250 F
0.0 to 5000
>0.0
>0.0
None
None
None
None
None
None
>0.0
>0.0
>0.0
-9 to +9
>0.0
None
None
None
>0.0
None
None
>0