DANIEL 2234 Manual page 63

Table of Contents

Advertisement

MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
Error Code
Possible Cause
00
1. Densitometer not
Analog
used.
density
transducer
out of range
2. Incorrect zero or
NOTE: Error
full scale entered for
Code is
densitometer.
active if
DENTYP is
3. Densitometer output
"1".
is greater than 102%.
4. Density out of
range, densitometer
malfunctioning or mis-
calibrated, wiring
error.
SECTION 2
Table 2-5. Error Code Diagnostic Chart
Check
1. Check VAR value
of read code 0
(DEN-LBF3).
1. Check values of
read codes 12 (DFS)
and 13 (DZ).
1. If read code 0 value
is greater than read
code 12;
1. If read code 0 value
is less than read code
13;
Solution
1. Place read code 0
in FXD mode. Enter
average density
(paragraph 3.6.2).
1. Enter correct full
scale and zero values
per paragraph 3.6.5.
1. Check wiring.
2. Verify density
3. Check
densitometer.
1. Check wiring.
2. Verify density.
3. Check
densitometer.
51

Advertisement

Table of Contents
loading

Related Products for DANIEL 2234

Table of Contents