__________________________ MODEL 2234 DIGITAL FLOW COMPUTER
E.
Line Extension (EXn) - Read Code 27n
The extension factor for a selected line number (n), used by the computer to
calculate the Reynolds factor for the line, may be displayed by using Read
Code 27n. The line extension display is the square root of
(HWn x PF). FXD values of any positive real number can be entered for
test purposes only. FXD value entries will affect flow totals if the computer
is on-line.
F.
Line Discharge Coefficient (CDn) - Read Code 28n
The discharge coefficient is calculated by the flow computer in accordance
with procedure 3.2.9 of Chapter 14.3.4 of the Manual of Petroleum
Measurement Standards, May 6, 1991. FXD values from 0.0 and above may
be entered for testing purposes only.
G.
Line Expansion Factor (Yn) - Read Code 29n
The expansion factor for a selected line number (n) may be displayed by
using Read Code 29n. FXD values from 0.0 and above may be entered for
testing purposes only. Typical values may be between 0.87 and 1.04.
90