DANIEL 2234 Manual page 109

Table of Contents

Advertisement

MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
C.
Use API-2565 - Command Code 7
Command Code 7 instructs the computer to use density as calculated from
temperature and pressure in the rate and totalization calculation.
computer will acknowledge this command code if the "enable/disable" switch
is in the "enable" position (green LED illuminated).
D.
Disable Error Code 8 - Command Code 12
Command Code 12 deactivates sensing for and turns OFF the Low
Temperature Alarm (Error Code 8). The computer will acknowledge this
command code even if the "Enable Disable" switch is in the "Disable"
position.
E.
Enable Error Code 8 - Command Code 13
Command Code 13 initiates sensing the Low Temperature Alarm (Error
Code 8).
"Enable/Disable" switch is in the "Disable" position.
F.
Display Error Code 8 - Command Code 14
Command Code 14 causes the computer to display the status of the Low
Temperature Alarm (Error Code 8). The display is shown as ER8 ENA if
the alarm is enabled; as ER8 DIS if the alarm is disabled. The computer
will acknowledge this command even if the "Enable/Disable" switch is in the
"Disable" position.
SECTION 3
The computer will acknowledge this command even if the
The
97

Advertisement

Table of Contents
loading

Related Products for DANIEL 2234

Table of Contents