4 - 20 mA Rate - Mass
1.
2.
3.
C.
Density, 0 - 10 V
1.
2.
3.
4.
D.
Density, 4 - 20 mA2
1.
2.
3.
4.
6
Range - 4 to 20 mA signal scalable by keyboard entry to
represent from 0.00 to N pounds per hour. Absolute
maximum range is 4 to 21 mA.
Maximum Load Resistance - 900 Ohms (18 V) to common.
Response Time - Differential Pressure Input to Rate Output -
2 seconds typical.
Range - 0.00 to +10.00 V signal, scalable by keyboard entry
to represent X to Y pounds per cubic foot. Absolute
maximum range is zero to 10.62 Volts.
Maximum Load - 5 mA (2 K Ohms minimum).
Response Time, Densitometer input to Density Output -
2 seconds, typical (for densitometer mode).
Response Time, Temperature and/or Static Pressure Input to
Density Output - 4 seconds, typical (for API-2565 mode).
Range - Four to 20 mA signal, scalable by keyboard entry to
represent X to Y pounds per cubic foot. Absolute maximum
range is 4 to 21 mA.
Maximum Load Resistance - 900 Ohms (18 V) to common.
Response Time, Temperature and/or Static Pressure Input to
Density Output - 4 seconds, typical (for API-2565 mode).
Response Time, Densitometer Input to Density Output -
2 seconds, typical (for densitometer mode).