DANIEL 2234 Manual page 132

Table of Contents

Advertisement

__________________________ MODEL 2234 DIGITAL FLOW COMPUTER
3.9.4.2 BARTON DENSITOMETERS
From the densitometer calibration certificate the following is determined:
1.
Units of calibration are: gm/cc
2.
Calibration temperature is: 70
3.
Calibration pressure is: 14.7 PSI
4.
Coefficient data is:
5.
Equation from data sheet is:
Pressure coefficient = +0.0014 GM/cc/1000 PSI
Temperature coefficient = -0.0054 GM/cc/100
120
o
F
A = 7.4145
B = 0.6917
o
F
SECTION 3

Advertisement

Table of Contents
loading

Related Products for DANIEL 2234

Table of Contents