3 Calibration
3.16. Resetting of Levelmeter 2000 and sensor
Sensor mounted on fixture
When using the sensor as a reference sensor it is fitted to the sensor fixture, together with a
sensor plate, as shown below.
See the section
orientation of the fixture and the sensor, since the direction of the sensor differs depending on
which axis is calibrated.
xx0100000207
A
B
C
Required equipment
Equipment
Levelmeter, one sensor
Sensor plate
Sensor fixture
Isopropanol
NOTE!
Always secure the sensor to the sensor fixture using screws and with approximately the same
torque each time!
NOTE!
Always fit the sensor in the same direction when resetting it as when performing the
calibration for each axis!
NOTE!
Always reset the sensor when using it in a new direction!
70
Positions and directions of sensor
Reference sensor, fitted to the sensor plate (actual direction differs)
Sensor fixture, fitted on robot base
Attachment screws, sensor plate
Art. no.
6369 901-347
3HAC 0392-1
6808 0011-GM
1177 1012-108
on page 25 for actual positioning and
Note
Includes one sensor.
For cleaning the sensor fixture.
3HAC 022907-001 Revision: -