3.9. Calibration, axis 2

3.9. Calibration, axis 2
General
This section details how to perform the actual fine calibration of axis 2 using the alternative
method with Levelmeter 2000 and is applicable for all robot models.
Required equipment
Equipment
Levelmeter 2000
Sensor plate
Angle bracket
Isopropanol
Other tools and procedures
may be required. See
references to these
procedures in the step-by-
step instructions below.
TIP!
Lock the axes previous to the one calibrated to minimize the risk of accidentally moving other
axes! In case of accidental movement of previous axes, the calibration procedure must be
restarted from the moved axis and continued in increasing sequence!
Calibration, axis 2
Step
52
Art. no.
6369 901-347 (incl. one sensor)
3HAC 0392-1
6808 0011-LP
1177 1012-108
Action
1.
Reset the levelmeter and the sensor for
calibration of axis 2.
2.
Remove the cover from the calibration surface on
the lower arm and clean the surface with
isopropanol.
3.
Fit the angle bracket on the lower arm.
Adjust the angle of the bracket to make it level.
4.
Fit the calibration sensor together with the sensor
plate on the angle bracket on axis 2.
Carefully tighten the securing screws with
approximately the same tightening torque used at
the reference plane!
Note
Only one sensor required.
For calibration sensor on
robot lower arm.
For cleaning the attachment
points.
These procedures include
references to the tools
required.
Note
Detailed in section
Resetting of
Levelmeter 2000 and sensor
page 69.
Art. no. is specified above in
Required
equipment.
Art. no. is specified above in
Required
equipment.
Note! With some of the early
IRB 7600, the M8 screw must be
replaced with an M6 x 25 and flat
washer when fitting the bracket!
Shown in section
Positions and
directions of sensor
on page 25!
3HAC 022907-001 Revision: -