Emergency Stop Switch [Side 2 Option]

WARNING:
To prevent electrical shock, disconnect from power source before installation or service.
The emergency stop button (E-STOP) shown in Figure 23 is used as an emergency shutdown device to terminate
power and stop the flow of fuel to the dispenser. A second E-Stop button is optional for Side 2 of the CNG Dispenser.
When the E-STOP button is pushed from the OUT position to the IN position the electrical contacts disengage and
power is terminated to the dispenser. When the E-STOP button is pulled from the IN position to the OUT position, the
electrical contacts are restored, and power can be returned to the dispenser.

Manual Shut Off (Ball Valve)

WARNING: To prevent electrical shock, disconnect from power source before installation or service.
There is one shut off valve for each CNG bank (Low, Mid, and High) located at the inlet of the dispenser as shown in
Figure 24. The shut off valve is used to remove or restore the flow of CNG into the dispenser for safety and/or
maintenance. Refer to the original manufacturer instructions for detailed information.
Follow the instructions below to remove or restore the flow of CNG.
1.
Turn the handle to remove flow from the dispenser.
2.
Turn the handle in the opposite direction to restore flow to the dispenser.
Safety Systems
Figure 23 - Emergency Stop (E-STOP)
Figure 24 - Shut Off Valve (Side 2 View)
18