Power One AURORA PVI-OUTD-US Series Installation And Operator's Manual page 61

Photovoltaic inverters
Table of Contents

Advertisement

Installation and Operator's Manual
(PVI-3.0/3.6/4.2-OUTD-x-US Rev: 2.1)
Message
Warning
Z Grid HI
W008
Int.Error
---------
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Int.Error
Fan Fail
W010
Int.Error
W012
W013
Error
type
//
//
E024
//
E025
//
E026
//
E027
//
E028
//
E029
//
E030
//
E031
//
E032
//
//
E033
//
E034
//
E035
//
E036
//
//
Description
Z grid out of range
Impedance outside range
Unknown Error –
Internal Error
Riso Low (Log Only)
Low insulation resistance (Log only)
Vref Error
Wrong reference voltage (VRef)
Vgrid Measures Fault
Grid voltage (VGrid) misreading
Fgrid Measures Fault
Grid frequency (FGrid) misreading
Zgrid Measures Fault
Grid impedance (ZGrid) misreading
Ileak Measures Fault
Leak current (ILeak) misreading
Wrong V Measure
Voltage (V) misreading
Wrong I Measure
Current (I) misreading
Fan Fail (No disconnection)
Fan faulty (Log Only)
UnderTemperature
Internal temperature
Interlock Fail (Not Used)
Remote Off
Remote power-off
Vout Avg
Average output voltage outside range
Clock Battery Low (No disconnection)
Clock battery low (not operating)
Clock Failure (No disconnection)
Clock faulty (not operating)
Page 61 of 108