ORBUS ERROR
The Power Converter has reported
a problem
Max sensor
The maximum number of sensors
has been exceeded
Serial # invalid
The Control unit does not have a
valid serial number
Sensor firmware
The version of the firmware inside
too old
the sensor is too old
56 / 82 | WEED-IT Quadro | User Manual - BT-UMWEEDQ-B
Check the Control unit connection
cables (between the Power
converter and the Control unit) for
physical damage.
Check the Power converter for any
damage. Open the lid and check
for any signs of short circuits or
moisture inside.
Contact your supplier immediately
and report any findings.
This setting can only be changed
by the manufacturer. Please
contact us.
Contact your supplier immediately
and have them replace the Control
unit.
If the error occurs after a sensor
replacement, your supplier must
update the sensor firmware. If this
problem occurs without changing
the sensors, there is a
communication problem between
one of the sensors and the Control
unit. Follow the same procedure as
you would in case of a COM error.
The sensor with the
communication issue is in this case
not the one with the x, but the
sensor that shows a software
version 0.00 in the sensor
information menu (100).