Zone Division System - ABB FlexTrack IRT501 Series Product Manual

Table of Contents

Advertisement

3 Maintenance

3.5.5 Zone division system

3.5.5 Zone division system
General
It is recommended to ensure the zone division is working properly every month.
Zone division system
The figure below shows the location of the position switch:
xx1800001989
Inspect monthly the following parts:
A
B
C
D
Verification of the effectiveness of the zone division sensor
If a 1 position, 2 position or 4 position limit switch is used to divide the track into
zones, then the following procedure should be followed to ensure it is functioning
correctly:
1
2
3
Continues on next page
136
Limit switch
Cam guide (on both ends of the FlexTrack)
Cam (on both ends of the FlexTrack)
Hard stop (bumper) (on both ends of the FlexTrack)
Action
Power off the IRC5 and activate the E-Stop.
Activate the limit switch sensor using an adhesive
tape.
Reset the E-Stop button and power on the
IRC5 in manual mode.
© Copyright 20042018 ABB. All rights reserved.
Note/Illustration
Product manual - FlexTrack IRT501-66/66R/90/90R
3HAW050008590-001 Revision: C