Analog Outputs

The drive has two 8 bit Analog Outputs which may be used for diagnostics, monitoring or
control purposes. These outputs are referred to as Channel 1 and Channel 2. They can be
accessed from the Command Connector on the drive or from the diagnostics output pins
located on the front of the drive.
Each Channel provides a programmable Analog Output Source.
Analog Output Source options are:
Velocity Command
Velocity Feedback
Torque Command (equates to Torque Command Actual parameter)
Torque Feedback
Following Error
Default Analog Output Source:
Channel
1
2
Each channel includes a programmable Analog Output Offset and an Analog Output Scale.
This feature allows you to "zoom in" to a desired range effectively increasing the resolution.
The units for both of these parameters is dependent upon the Analog Output Source selection.
Analog Output Offset units:
Velocity Command = RPM
Velocity Feedback = RPM
Torque Command = Percent of continuous torque for selected motor
Torque Feedback = Percent of continuous torque for selected motor
Following Error = Revs
Analog Output Scale units:
Velocity Command = RPM/volt
Velocity Feedback = RPM/volt
Torque Command = Percent of continuous torque/volt for selected motor
Torque Feedback = Percent of continuous torque/volt for selected motor
Following Error = Revs/volts
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Output Source
Offset
Velocity Feedback
0
Torque Command
0
Operational Overview
Scale
600 RPM/volt
30 percent/volt for selected motor
31