Mechanical Installation - Emerson Control Techniques Epsilon Eb Series Reference Manual

Table of Contents

Advertisement

Epsilon Eb and EN Drives Reference Manual
Environmental Considerations
If the product will be subjected to atmospheric contaminants such as moisture, oils,
conductive dust, chemical contaminants and metallic particles, you must mount it vertically
in a metal NEMA type 12 enclosure.
If the ambient temperature inside the enclosure will exceed 40° C (104° F), you must consider
forced air cooling.
Note
It is necessary to maintain the drive surround air ambient temperature at 40° C (104° F)
[50°C (122ºF) with derating of 3% per degree above 40° C].
The amount of cooling depends on the size of the enclosure, the thermal transfer of the
enclosure to the ambient air and the amount of power being dissipated inside the enclosure.
Consult your enclosure manufacturer for assistance with determining cooling requirements.
Wiring Notes
To avoid problems associated with EMI (electromagnetic interference), you should route
high power lines (AC input power and motor power) away from low power lines (encoder
feedback, serial communications, etc.).
If a neutral wire (not the same as Earth Ground), is supplied from the building distribution
panel it should never be bonded with PE wire in the enclosure.
You should consider future troubleshooting and repair when installing all wiring. All
wiring should be either color coded and/or tagged with industrial wire tabs.
As a general rule, the minimum cable bend radius is ten times the cable outer diameter.
All wiring and cables, stationary and moving, must be protected from abrasion.
Ground wires should not be shared with other equipment.
Ensure that metal to metal contact is made between the enclosure ground lug and the metal
enclosure, not simply through the mounting bolt and threads.
All inductive coils must be suppressed with appropriate devices, such as diodes or
resistor/capacitor (RC) networks.

Mechanical Installation

Drive Mounting
Drives must be back mounted vertically on a metal surface such as a NEMA enclosure. A
minimum spacing of two inches must be maintained above and below the drive for
ventilation. Additional space may be necessary for wiring and cable connections.