Safety
1.4
- The capaNCDT 61x0/IP measuring system is designed for use in industrial areas. It is used for
- The system must only be operated within the limits specified in the technical data, see Chap.
1.5
- Protection class:
- Operating temperature:
- Humidity:
- Ambient pressure:
- Storage temperature:
- The space between the sensor surface and the target must have an unvarying dielectric constant.
- The space between the sensor surface and the target may not be contaminated (for example water,
capaNCDT 61xx/IP
Intended Use
displacement, distance, thickness and movement measurement
position measuring of parts or machine components
The system must be used in such a way that no persons are endangered or machines and other materi-
al goods are damaged in the event of malfunction or total failure of the system.
Take additional precautions for safety and damage prevention in case of safety-related applications.
Proper Environment
Sensor
IP 40, IP 54 (functionality reduced)
Controller
IP 68
Sensor:
-50 ... +200 °C (-58 to +392 °F), type CSE
-40 ... +100 °C (-40 to 212 °F), type CSF
Sensor cable:
-20 ... +80 °C (-4 to 176 °F) (permanently)
-20 ... +100 °C (-4 to 212 °F) (up to 10,000 h)
Controller:
-20 ... +60 °C (-4 to 140 °F)
5 - 95 % (non-condensing)
Atmospheric pressure
Sensor:
-50 ... +200 °C (-58 to +392 °F), type CSE
-40 ... +100 °C (-40 to 212 °F), type CSF
Sensor cable:
-50 ... +80 °C (-58 to 176 °F)
Controller:
-20 ... +75 °C (-4 to 167 °F)
rubbed-off parts, dust, etc.).
2.3.
Seite 7
Need help?
Do you have a question about the capaNCDT 6110 IP and is the answer not in the manual?
Questions and answers