3
C SAFE ON/OFF buttons
RECALL ON/OFF buttons
The function of these buttons will depend on the
2 ) setting.
SELECTION MODE (
If the SAFE PARAMETER button is on
These buttons function as SAFE ON/OFF buttons that
specify the channels excluded from recall operations.
If the RECALL PARAMETER button is on
These buttons function as RECALL ON/OFF buttons
that specify the channels that will be recalled.
D Parameter matrix grid
Here you can select the parameters that will be recalled
(or excluded from recall). SAFE PARAMETER selec-
tions are shown in green, and RECALL PARAMETER
selections are shown in blue. If the ALL button is on, all
parameters other than CH to MIX will be recalled (or
excluded from recall).
Note
• Matrix grids corresponding to combinations that cannot be
selected are grayed-out.
• Settings in the parameter matrix grid are ignored for chan-
nels whose SAFE ON/OFF button or RECALL ON/OFF
button is switched off.
E ASSIGN
This area indicates the number of assigned channels for
each parameter.
F SET ALL
These buttons turn on the buttons of all channels or all
buttons of the corresponding parameter.
G CLEAR ALL
These buttons turn off the buttons of all channels or all
buttons of the corresponding parameter.
4
5
6
7
PM5D/PM5D-RH Owner's Manual
H OTHER SAFE/RECALL PARAMETERS
By using these buttons, parameters other than those
described above can be excluded from recall
operations.
If the SAFE PARAMETER button is turned on in the
2 ) area, these buttons specify
SELECTION MODE (
the parameters that will be excluded from recall. If the
RECALL PARAMETER button is turned on, these but-
tons specify the parameters that will be recalled.
I SET ALL
This button turns on all buttons of the OTHER SAFE
PARAMETERS area.
J CLEAR ALL
This button turns off all buttons of the OTHER SAFE
PARAMETERS area.
In the case of parameters (such as those listed below) for
which two adjacent odd-numbered/even-numbered chan-
nels or modules share a single parameter, the parameter
will be recalled (or excluded from recall) only if selective
recall is specified for both channels/modules.
• GATE STEREO LINK
• COMP STEREO LINK
• DELAY GANG
• PAN MODE
• GEQ LINK
• ATT GANG
• MS DECODE
• FIXED/VARI
Note
• Recall Safe and Selective Recall can be used together.
Channels/parameters excluded from recall operations by
either Recall Safe or Selective Recall (or both) will not be
recalled.
• Selective Recall applies when a scene is recalled in PRE-
VIEW mode.
• When you recall a scene, there may be cases in which a
conflict in pairing settings between Recall Safe and Selec-
tive Recall causes the settings of a parameter to differ
between L and R channels. In such cases, the parameter
will be linked when it is next operated.
Reference section
8
9
J
165