To change the timing of media-break detection

When the winding diameter of the media falls below the detection range of the remaining media sensor, the
media conveyance stops.
If conveyance stops even though sufficient media remains or conveyance does not stop even when the re-
maining media becomes insufficient, the problem may be solved by adjusting the remaining media sensor.
The detection range shall be set between the remaining media sensor and unwinder spindle. When you widen
this interval, the detection timing becomes earlier. When you reduce this interval, the detection timing be-
comes later.
1
Loosen the rotation knob of the remaining media sensor.
2
Adjust the position by measuring the interval between the remaining media sensor and unwinder spin-
dle.
3
After determining the position, securely tighten the rotation knob to fix the remaining media sensor.
NOTICE
% Normally, configure the default setting, 9 mm.
% When changing it, it is recommended to adjust it by the millimeter. You shall be responsible for
changes in the setting.
6-26
To change the timing of media-break detection
Recommended
detection range
9 mm
Remaining media sensor
Unwinder spindle
Rotation knob