Table 47: Parameter Data For Acyclic Access - WAGO I/O-SYSTEM 750 Manual

2ai 4-20ma hart ex i 2-channel analog input; hart; intrinsically safe, 2ai 4-20ma hart ne43 ex i 2-channel analog input; hart; namur ne43; intrinsically safe
Table of Contents

Advertisement

62
Operating Modes
Selection Parameters for 75x-484 2AI/4-20 mA/SE/ Ex i

Table 47: Parameter Data for Acyclic Access

Parameter
Acyclic
access to the
HMDs
*)
Default value
Manual
Version 1.4.0
Value
*)
• Disabled
• 12 Byte Mailbox
WAGO-I/O-SYSTEM 750
750-484 2AI 4-20mA HART Ex i
Description
• Acyclic access to the HMDs (HART
Master Devices) is deactivated
• 12-byte mailbox for acyclic access
activated

Advertisement