Deleting VME Settings
vmeCfg –e –r400: Edits Master Control Register state
vmeCfg –e –r40: Edits Miscellaneous Control Register state
vmeCfg –e –r40C: Edits User AM Codes Register state
vmeCfg –e –rF70: Edits VMEbus Register Access Image Control Register state
3.5.5
Deleting VME Settings
To delete the changeable VME setting (restore default value), type the following at the
firmware prompt:
vmeCfg –d –m: Deletes Master Enable state
vmeCfg –d –i(0 - 7): Deletes selected Inbound Window state
vmeCfg –d –o(0 - 7): Deletes selected Outbound Window state
vmeCfg –d –r184: Deletes PCI Miscellaneous Register state
vmeCfg –d –r188: Deletes Special PCI Target Image Register state
vmeCfg –d –r400: Deletes Master Control Register state
vmeCfg –d –r404: Deletes Miscellaneous Control Register state
vmeCfg –d –r40C: Deletes User AM Codes Register state
vmeCfg –d –rF70: Deletes VMEbus Register Access Image Control Register state
3.5.6
Restoring Default VME Settings
To restore all of the changeable VME setting back to their default settings, type the
following at the firmware prompt: vmeCfg –z
3.6
Remote Start
As described in the MOTLoad Firmware Package User's Manual, listed in
Related Documentation
board, download code and/or data, modify memory on the target, and execute a
downloaded program. These transactions occur across the VMEbus in the case of the
MVME3100. MOTLoad uses one of four mailboxes in the Tsi148 VME controller as the
inter-board communication address (IBCA) between the host and the target.
54
, remote start allows the user to obtain information about the target
MVME3100 Single Board Computer Installation and Use (6806800M28H)
MOTLoad Firmware
Appendix B,
Need help?
Do you have a question about the MVME3100 and is the answer not in the manual?