iDrive2 inverters
Appendix C Peripherial options and parts
This chapter describes how to select the options and parts of IMO XKL series inverters.
C.1 Peripherial wiring
Below is the peripherial wiring of IMO XKL series inverters.
Pictures
Name
Cables
Breaker
Input reactor
Input filter
Braking resistors
Output filter
Appendix C Peripherial options and parts
Description
Device to transfer the electronic signals
Prevent from electric shock and protect the power
supply and the cables system from overcurrent when
short circuits occur. (Please select the breaker with
the function of reducing high order harmonic and the
rated sensitive current to 1 inverter should be above
30mA).
This device is used to improve the power factor of
the input side of the inverter and control the higher
harmonic current.
Control the electromagnetic interference generated
from the inverter, please install close to the input side
of the inverter.
Shorten the DEC time.
Controls the interference from the output side of the
inverter. Install close to the output terminals of the
inverter.
87